Sign In | Join Free | My adobecards.com
China ShenzhenYijiajie Electronic Co., Ltd. logo
ShenzhenYijiajie Electronic Co., Ltd.
The company advocates the corporate culture of "integrity and dedication, pragmatic innovation, unity and cooperation, diligence and progress", pays attention to standardized management, advocates
Verified Supplier

3 Years

Home > Oxygen Gas Sensor >

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices

ShenzhenYijiajie Electronic Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices

  • 1
  • 2
  • 3

Brand Name : CITY

Model Number : MOX-3 MOX3 AA829-M10

Place of Origin : Britain

MOQ : 1

Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram

Supply Ability : 311/pcs/pre

Delivery Time : 3-5work days

Packaging Details : canned

Typical Applications : Critical care anesthesia

Operating Temperature Range : -20°C to +50°C

Operating Pressure Range : 0.5 Bar to 2.0 Bar

Operating Humidity Range : 0% to 99% RH non-condensing

Long-Term Ouput Drift in 100% O2 : < 5% signal loss/year

Recommended Storage Temperature : -10°C to +40°C

Contact Now

Product Description:

MOX-3 MOX3 AA829-M10 Oxygen Gas sensor Oxygen Battery For Medical Devices

Features:

The purpose of this document is to present the performance specification of the MOX3 oxygen gas sensor.

This document should be used in conjunction with the Operating Principles (OP04) and the Product Safety Datasheet (PSDS 4).

The data provided in this document are valid at 20°C, 50% RH and 1013 mBar for 3 months from the date of sensor manufacture.

Output signal can drift below the lower limit over time. For guidance on the safe use of the sensor, please refer to the Operating Principles (OP04).

CiTiceLs are designed for operation in a wide range of environments and harsh conditions. However, it is important that exposure to high concentrations of solvent vapours is avoided, both during storage, fitting into instruments and operation.
When using sensors with printed circuit boards (PCBs), degreasing agents should be used before the sensor is fitted. Do not glue directly on or near the CiTiceL as the solvent may cause crazing of the plastic.
Intended Use
These sensors are designed to be used to monitor the partial pressure of oxygen in anaesthesia (not including xenon), critical care, neonatal incubators, and general oxygen monitors.

Specifications:

Operating Principle Partial pressure electrochemical
Output 9 mV to 13 mV in 210 mBar O2
Measurement Range 0 mBar to 1500 mBar O2
Response Time (T90)* <15 s (air to 100% O2)
Baseline Offset* <200 μV
Linearity Linear 0% to 100% O2

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices


Product Tags:

MOX3 Oxygen Gas Sensor

      

Oxygen Gas Sensor AA829-M10

      

MOX-3 Oxygen Sensor

      
 MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices Manufactures

MOX3 MOX-3 Gas Oxygen Sensor AA829-M10 O2 Battery For Medical Devices Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: ShenzhenYijiajie Electronic Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)